-23%

FUSION ULTRA D/C DUAL CURING RESIN BASED LUTING CEMENT

1,150.00

Product Code: N/A Availability: Out of stock

Email when stock available

Description

Product Description :

Fusion Ultra D/C is a light and chemically cured low viscosity radiopaque, two
component polymer resin based composite adhesive for luting of composite and ceramic restoration.
Composition :
Base Paste : Bisphenol A Glycidyl Methacrylate, Ethoxlated Bisphenol A Dimethacrylate, Triethylene
Glycol Dimethacrylate, Silanated Barium Glass Powder, Amorphous Fumed Silica, Curing Agents and
Stabilizer.
Catalyst Paste : Bisphenol A Glycidyl Methacrylate, Ethoxlated Bisphenol A Dimethacrylate, Triethylene
Glycol Dimethacrylate, Silanated Barium Glass Powder, Amorphous Fumed Silica, Curing Agent and
Stabilizer.
Indications :
♦ Permanent cementation of crown and bridge.
♦ Permanent cementation of endodontic posts made of metal, reinforced composite.
♦ Permanent cementation of implant retained crowns.

Instructions for Use :

Dispense the material from syringe through automix tip. The initial set will occur in
2:00 2:30( min:sec) with a final set at 3-4 minutes. The cement may also be cured with a dental curing light
with a 40 second exposure.
1. Metal to Enamel/Dentin : Metal restorations to tooth structure-crowns, inlays, bridges, and posts
including Maryland and bridges) After try-in, sandblast each side of the restoration. Using a metal primer of
your choice, treat the metal exposed to the paste. Clean tooth with non-fluoridated prophy paste or pumice.
To prepare tooth for bonding, use a universal dentin / enamel bonding system. Mix equal Amounts of
catalyst and base pastes and use a plastic instrument or injection system to place in restoration. Avoid
trapping air bubbles. Seat Restoration on tooth and hold in place until paste reaches initial set (about 2:00-
2:30 minutes). Use a scaler or explorer to remove excess cement immediately upon initial set. It is not
important to wait until the final set to remove excess cement.
2. Metal to Metal : Implant prosthesis or crown on post. Sandblast all external metal surfaces to be
exposed to paste. Rough intra-oral metal with a micro-etcher or bur. Using a metal primer of your choice,
treat the metal exposed to the paste. Clean posts or Abutments with non-fluoridated prophy paste or
pumice. Mix equal amounts of catalyst and base pastes and use a plastic instrument or injection system to
place in restoration. Avoid trapping air bubbles. Seat restoration on tooth and hold in place until paste
reaches initial set (about 2:00–2:30 minutes). Use scaler or explorer to remove excess cement
immediately upon initial set. It is not important to wait until final set to remove excess cement.
3.Ceramic Restorations to Teeth (Porcelain Veneers, In-lays, On-lays) After try-in, etch ceramic restoration
and place in acetone or ethanol in ultrasonic cleaner for 1-2 minutes. Place silanating agent on internal or
porcelain restoration. Clear tooth with non-fluoridated prophy paste or pumice. To prepare tooth for
bonding, use a universal dentin / enamel bonding system. Mix equal amounts of catalyst and base pastes
and use a plastic instrument or injection system to place in Restoration. Avoid trapping air bubbles. Seat
restoration on tooth and hold in place until paste reaches initial set (about 2:00-2:30 minute) use scaler or
explorer to remove excess cement immediately upon initial set. It is not important to wait until final set to
remove excess cement.
Precautions and warnings : This product will adhere to metal instruments. Remove excess material from
the instrument immediately after using. The cement contains certain methacrylates and other ingredients
which may cause irritation or sensitivity in some individuals. If contact occurs with skin, immediately wash
with soap and water. Improper use may result in allergic reaction or skin and tissue irritation. If this occurs,
discontinue use of this product. Protective gloves and eye wear should be worn while handling this product.
If contact occurs with eye. Flush immediately with large volumes of water and seek medical attention
immediately. Do not expose materials to elevated temperatures or intense light. Do not store in the vicinity
of alcohol based materials. Do not remove or reverse the syringe caps as this may promote polymerization.

Storage Conditions :
Store between 10°C to 24°C. Close the syringe carefully after use. Keep Away from Moisture. Shelf Life
not affected after opening if stores in a cool dry place. If not to be used for a longer duration, keep them in
refrigerator. Allow material to reach room temperature prior to use
Shelf life :
2 years from the date of manufacturing.
Presentation :
Ref : 30006
Intro Pack : 1 x 9g Automix Syringe, 10 x Automix Tips.

Disposal conditions :
To be disposed off based on the prevailing rules of the country in which it is used

Reviews

There are no reviews yet.


Be the first to review “FUSION ULTRA D/C DUAL CURING RESIN BASED LUTING CEMENT”