Hot
-67%

Hanu Dent Airotor Handpiece Standard Head – Push Button (SL213C-TU)

1,500.00

Hanu Dent Airotor handpiece standard head push button type has been designed for a professional to achieve a significant reduction in procedural times. Better grip contributes to a specialized level of visibility and maneuverability for users to access hard to reach and see areas with greater accuracy and precision.

Packaging

  • 1x Handpiece SU
  • 1x User Manual
Product Code: N/A Availability: Out of stock

Email when stock available

Description

Hanu Dent standard head push button Airotor handpiece is specially designed for comfort and ease of use, reducing patient chair time and discomfort. The prices are also most economical and in accordance with the Hanu Dent brand motto of providing excellent service at affordable costs.

Additional information

Weight 0.5 kg
Dimensions 10 × 2 × 1 cm

Reviews

There are no reviews yet.


Be the first to review “Hanu Dent Airotor Handpiece Standard Head – Push Button (SL213C-TU)”

  • Stylish
  • Good Quality Cartridge
  • Autoclavable up to 135 C
  • Exclusive Design
  • Integral stainless steel body with resistance to scratch.
  • Lightweight
  • Integrated machining & forming head.
  • Strong power
  • Low Noise with enhanced cutting efficiency.
  • Head Size : Standard
  • Ceramic ball bearing
  • Fitting : 2 Holes/ Normal Fitting
  • Water Spray : Single
  • Wrench Type : Push Button
  • Bur Size : 1.59 – 1.60 mm.
  • Air Pressure :0.18-0.21 MPa (0.18~0.21 MPa (1.8~2.1kgf/cm2))
  • Speed : 350000-400000rpm.

Causions

Place the most priority of the patient’s safety.
• For professional use only. Do not make wrong use of the handpiece.
• Do not disassemble, nor alter the handpiece.
• Check the vibration, noise and overheating outside the patient’s oral cavity before use. If any abnormalities are found, stop using immediately and contact your dealer. Of
• If any abnormalities are found in use, stop using immediately any contact your dealer.
• After extended use the handpiece may become noisy, replace the cartridge with a new one. Failure to replace the cartridge may cause accidents or impair operator’s hearing.
Depressing the push-button while handpiece bur is in rotation will result in overheating of the
• handpiece head, Special caution must be exercised during use to keep cheek tissue away from the push-button of the handpiece. Contact with cheek tissue may cause the push-button to depress and injury to the patient may occur.
• Do not drop, hit, or subject to excessive shock.
• Do not use bent, damaged, or sub-standard burs. The shank could be bent or broken even within the recommended speed.
• Always keep the bur shank clean. Entry of debris into the chuck could cause bur run-out and the bur could not be mounted inmost.
• Do not exceed the bur manufacturer’ recommended speed.
• Do not operate the handpiece without the bur or test-bur.
• Always nount the bur or the test-bur even when the handpiece is not in use.
• Remove the bur or the test-bur after the air supply is stopped completly.